Coating Specification
New building ships (both coastal and ocean-going)
Repair ships (ocean-going vessels, large vessels)
Repair ships (coastal vessels, small ships)
New building ships (both coastal and ocean-going)
OPEN
CLOSE
Ship bottom area
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy / Vinyl binder system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
200 | 16H | 7D |
UNIVERSAL PRIMER NT TAKATA QUANTUM※1 TAKATA QUANTUM※1 |
50 ※2 ※2 |
4H ※2 ※2 |
Free※3 ※2 ※2 |
|
Epoxy / Epoxy binder system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
150 | 16H | Free※4 |
EPOMARINE AC MARK 2 TAKATA QUANTUM※1 TAKATA QUANTUM※1 |
100 ※2 ※2 |
16H ※2 ※2 |
5D ※2 ※2 |
|
|
Boot top area
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy / Acrylic system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
150 | 16H | 7D |
PIONER PLUS PIONER PLUS |
40 40 |
4H 4H |
Free※3 Free※3 |
|
Epoxy system | EPOMARINE AC(M) or EPOMARINE AC(M)HS |
150 | 16H | Free※4 |
EPOMARINE BTD EPOMARINE BTD |
40 40 |
10H 10H |
Free※3 Free※3 |
|
Epoxy / Urethane system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
150 | 16H | 7D |
RETAN 6000 RETAN 6000 |
30 30 |
16H 16H |
Free※3 Free※3 |
|
|
Topside area
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy / Acrylic system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | 7D |
PIONER PLUS PIONER PLUS |
40 40 |
4H 4H |
Free※3 Free※3 |
|
Epoxy system | EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | Free※2 |
EPOMARINE BTD EPOMARINE BTD |
40 40 |
10H 10H |
Free※3 Free※3 |
|
Epoxy / Urethane system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | 7D |
RETAN 6000 RETAN 6000 |
30 30 |
16H 16H |
Free※3 Free※3 |
|
|
Upper deck / Fittings
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy / Acrylic system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | Free※4 |
PIONER PLUS PIONER PLUS |
40 40 |
4H 4H |
Free※3 Free※3 |
|
Epoxy system | EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | Free※4 |
EPOMARINE BTD EPOMARINE BTD |
40 40 |
10H 10H |
Free※3 Free※3 |
|
Modified Epoxy system | EPOMARINE EX500 EPOMARINE EX500 |
100 100 |
16H 16H |
Free※3 Free※3 |
|
Superstructure(ext)
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy / Acrylic system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | Free※4 |
PIONER PLUS PIONER PLUS |
40 40 |
4H 4H |
Free※3 Free※3 |
|
Epoxy system | EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | Free※4 |
EPOMARINE BTD EPOMARINE BTD |
40 40 |
10H 10H |
Free※1 Free※3 |
|
Epoxy / Urethane system |
EPOMARINE AC(M) or EPOMARINE AC(M)HS |
125 | 16H | 7D |
RETAN 6000 RETAN 6000 |
30 30 |
16H 16H |
Free※3 Free※3 |
|
|
Ballast tank
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS |
125 125 |
16H 16H |
7D 7D |
Epoxy system (PSPC)※6 |
EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS (Double Stripe coat essential) |
160 160 |
16H 16H |
7D 7D |
|
Crude oil cargo tank, ballast multi-purpose tank, slop tank
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE EX600 EPOMARINE EX600 |
125 125 |
16H 16H |
7D 7D |
Epoxy system (PSPC)※6 |
EPOMARINE AC(M) EPOMARINE AC(M) |
160 160 |
16H 16H |
7D 7D |
|
Tank for drinking water
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE FW-NS | 300 | 36H | 7D |
Product /Chemical tank
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE PRIMER PC EPOMARINE PC100 UNDERCOAT EPOMARINE PC100 TOPCOAT |
50 125 125 |
12H 16H 16H |
7D 7D 7D |
Inorganic zinc system | SD ZINC 1500A | 90 | 48H | Free※3 |
|
Hold
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE AC(M) or EPOMARINE AC(M)HS |
200 | 16H | Free※4 |
Epoxy system (Dry hold) |
EPOMARINE EX500 | 150 | 16H | Free※3 |
Epoxy system (Hold + Ballast double use) |
EPOMARINE EX600 | 200 | 16H | 7D |
|
Interior ※7
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Alkyd paint system | SD MARINE BUILD PRIMER SD MARINE BTD SD MARINE BTD |
80 35 35 |
12H 15H 15H |
Free※3 Free※3 Free※3 |
High temperature and humidity, Alkyd paint system |
SD MARINE BUILD PRIMER(M)KAI SD MARINE BTD SD MARINE BTD |
80 35 35 |
16H 15H 15H |
Free※3 Free※3 Free※3 |
Epoxy system | EPOMARINE EX500 EPOMARINE EX500 |
80 80 |
16H 16H |
Free※3 Free※3 |
|
Tank for lubricant oil
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE PC100 UNDERCOAT EPOMARINE PC100 TOPCOAT |
100 100 |
16H 16H |
7D 7D |
Void /Cofferdam
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Epoxy system | EPOMARINE EX500 | 100 | 16H | Free※3 |
Alkyd paint system | SD MARINE BUILD PRIMER | 80 | 12H | Free※3 |
|
High temperature part ※8
Swipe to see the entire table
Type | Product name | DFT (µm/coat) |
Painting interval(20℃) | |
---|---|---|---|---|
MIN. | MAX. | |||
Aluminum paint system | SD MARINE BUILD PRIMER | 80 | 12H | Free※3 |
PLATINITE R or SD MARINE BTD Silver※9 |
20 20 |
16H 16H |
Free※3 Free※3 |
|
Silicon paint system | THERMO M 300 UNDERCOAT THERMO M 300 Silver |
30 20 |
12H 12H |
Free※3 Free※3 |
Silicon paint system (high temperature) |
THERMO M 600 Silver THERMO M 600 Silver |
30 20 |
12H 12H |
Free※3 Free※3 |
|
Repair ships (ocean-going vessels, large vessels)
OPEN
CLOSE
Ship bottom area
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance case) Attached creatures and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film and barnacles should be removed by scraper. Rusty spots should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. In case, powertool applied grade should be ISO 8501-1(SIS)St3. |
EPOMARINE AC(M) VINITECT PRIMER TAKATA QUANTUM series |
Touch-up Touch-up Full coat |
1 coat 1 coat 2 coat |
200 50 ※ |
(All over maintenance case) Attached creatures and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Full area should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. |
SD ZINC 100QD EPOMARINE AC(M) VINITECT PRIMER TAKATA QUANTUM series |
Full coat Full coat Full coat Full coat |
1 coat 1 coat 1 coat 2 coat |
25 200 50 ※ |
|
Boot top /Top side area
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
Surface preparation Coating Specification DFT (µm/coat) Attached creatures and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film and barnacles should be removed by scraper. Rusty spots should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. In case, powertool applied grade should be ISO 8501-1(SIS)St3. |
APEX AC PIONER PLUS |
Touch-up Full coat |
3 coat 1 coat |
70 40 |
EPOMARINE AC(M) VARIOUS TOPCOAT |
Touch-up Full coat |
2 coat 1 coat |
100 ― |
Hold
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance case) Dust and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film should be removed by scraper. Rusty spots should be treated by powertool to ISO 8501-1(SIS)St3 |
EPOMARINE AC(M) | Touch-up | 1 coat | 200 |
(All over maintenance case) Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Full area should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. Dust on the surface should be removed thorough before coating. |
SD ZINC 100QD | Full coat | 1 coat | 25 |
- Remark:DFT for Ballast/ Hold double use is more than 250µm
Ballast tank
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance by Barrier) Salt and sludge should be cleaned by fresh water washing and let the surface dry. Oil & fat should be removed by solvent or chemical cleaner wipe. Loose rusts and paint film should be removed by scraper. Existing paint film surface should be roughened by wire-brush or sand-paper. |
NuFORTE BARRIER | Touch-up | 1-2 coat | 1000 -2000 |
(Spot maintenance on Pre-PSPC film) Super high pressure water washing (Hydrojet more than 15,000psi) or powertool treatment on the rusty/damaged spots to more than ISO 8501-1(SIS)St2. Other area should be high pressure water washed and remove dirt and salt. |
NuFORTE DX NuFORTE DX |
Touch-up Full coat |
1 coat 1 coat |
200 150 |
(※PSPC) Maintenance & Midterm Repair (5-10years) Surface Preparation (St3.0 or Sa2.5) |
EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS (Double Stripe coat essential) |
Spray coat Spray coat |
1 coat 1 coat※ |
125 125 |
(※PSPC) Maintenance & Midterm Repair (5-10years) Surface Preparation (St3.0 or Sa2.5) |
EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS (Double Stripe coat essential) |
Spray coat Spray coat |
1 coat 1 coat |
160 160 |
- ※MSC.1/Circ.1330 (GUIDELINES FOR MAINTENANCE AND REPAIR OF PROTECTIVE COATINGS)
Maintenance = By ship's crew on board, Repair = By shipyard
Repair ships (coastal vessels, small ships)
OPEN
CLOSE
Ship bottom(2 year specification)
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance case) Attached creatures and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film and barnacles should be removed by scraper. Rusty spots should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. In case, powertool applied grade should be ISO 8501-1(SIS)St3. |
APEX AC TAKATA QUANTUM series / SHIN LLL series |
Touch-up Full coat |
3 coat 2 coat |
70 ※ |
VINITECT PRIMER TAKATA QUANTUM series / SHIN LLL series |
Touch-up Full coat |
3 coat 2 coat |
70 ※ |
|
NuFORTE APEX AC TAKATA QUANTUM series / SHIN LLL series |
Touch-up Touch-up Full coat |
1 coat 1 coat 2 coat |
200 50 ※ |
|
(All over maintenance case) Attached creatures and salt should be removed by high pressure washing. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Full area should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. |
SD ZINC 100QD EPOMARINE AC(M) UNIVERSAL PRIMER NT TAKATA QUANTUM series / SHIN LLL series |
Full coat Full coat Full coat Full coat |
1 coat 1 coat 1 coat 2 coat |
25 200 50 ※ |
|
Boot top /Top side area
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
Attached creatures and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film and barnacles should be removed by scraper. Rusty spots should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. In case, powertool applied grade should be ISO 8501-1(SIS)St3. |
APEX AC PIONER PLUS |
Touch-up Full coat |
3 coat 1 coat |
70 40 |
NuFORTE EPOMARINE BTD |
Touch-up Full coat |
2 coat 1 coat |
100 40 |
|
EPOMARINE AC(M) RETAN 6000 |
Touch-up Full coat |
2 coat 1 coat |
100 30 |
Hold
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance case) Dust and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Loose film should be removed by scraper. Rusty spots should be treated by powertool to more than ISO 8501-1(SIS)St2 |
NuFORTE or EPOMARINE EX500 |
Touch-up | 1 coat | 150 |
(All over maintenance case) Dust and salt should be removed by high pressure water washing and let the surface dry. Dirt, oil, grease etc. should be removed by solvent or chemical cleaner wipe. Full area should be sandblasted to more than ISO8501-1 (SIS)Sa2.5. Dust on the surface should be removed thorough before coating. |
SD ZINC 100QD | Touch-up | 1 coat | 25 |
Ballast tank
Swipe to see the entire table
Surface preparation | Coating Specification | DFT (µm/coat) |
||
---|---|---|---|---|
(Spot maintenance by Barrier) Salt and sludge should be cleaned by fresh water washing and let the surface dry. Oil & fat should be removed by solvent or chemical cleaner wipe. Loose rusts and paint film should be removed by scraper. Existing paint film surface should be roughened by wire-brush or sand-paper. |
NuFORTE BARRIER | Touch-up | 1-2 coat | 1,000?2,000 |
(Spot maintenance on Pre-PSPC film) Super high pressure water washing (Hydrojet more than 15,000psi) or powertool treatment on the rusty/damaged spots to more than ISO 8501-1(SIS)St2. Other area should be high pressure water washed and removed dirt and salt. |
NuFORTE DX NuFORTE DX |
Touch-up Full coat |
1 coat 1 coat |
200 150 |
(※PSPC) Maintenance & Midterm Repair (5-10years) Surface Preparation (St3.0 or Sa2.5) |
EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS (Double Stripe coat essential) |
Spray coat Spray coat |
1 coat 1 coat※ |
125 125 |
(※PSPC) Long term Repair (10years over) Surface Preparation(St3.0 or Sa2.5) |
EPOMARINE EX21 PLUS EPOMARINE EX21 PLUS (Double Stripe coat essential) |
Spray coat Spray coat |
1 coat 1 coat |
160 160 |
- ※MSC.1/Circ.1330 (GUIDELINES FOR MAINTENANCE AND REPAIR OF PROTECTIVE COATINGS)
Maintenance = By ship's crew on board, Repair = By shipyard